Code | Module/Unit of Competency | Weighting Points | Nominal Hours |
CORE UNITS OF COMPETENCY Competencies marked * have pre-requisite competencies |
UEECD0007 | Apply work health and safety regulations, codes and practices in the workplace | 20 | 20 |
UEECD0016 | Document and apply measures to control WHS risks associated with electrotechnology work* | 20 | 20 |
UEECD0019 | Fabricate, assemble and dismantle utilities industry components* | 40 | 40 |
UEECD0020 | Fix and secure electrotechnology equipment* | 20 | 20 |
UEECD0042 | Solve problems in ELV single path circuits* | 40 | 40 |
UEECD0051 | Use drawings, diagrams, schedules, standards, codes and specifications* | 40 | 40 |
UEECO0010 | Participate in refrigeration and air conditioning work and competency development activities | 60 | 20 |
UEERA0031 | Diagnose and rectify faults in air conditioning and refrigeration control systems* | 60 | 80 |
UEERA0035 | Establish the basic operating conditions of air conditioning systems* | 20 | 20 |
UEERA0036 | Establish the basic operating conditions of vapour compression systems* | 60 | 60 |
UEERA0044 | Find and rectify faults in single phase motors and associated controls* | 40 | 40 |
UEERA0045 | Find and rectify faults in three phase motors and associated controls* | 30 | 30 |
UEERA0050 | Install refrigerant pipe work, flow controls and accessories* | 60 | 60 |
UEERA0051 | Install, commission, service and maintain air conditioning systems* | 80 | 80 |
UEERA0052 | Install, commission, service and maintain low temperature systems* | 40 | 40 |
UEERA0053 | Install, commission, service and maintain medium temperature systems* | 60 | 40 |
UEERA0059 | Prepare and connect refrigerant tubing and fittings* | 40 | 40 |
UEERA0062 | Recover and charge refrigerants* | 40 | 40 |
UEERA0079 | Safely handle refrigerants and lubricants* | 40 | 40 |
UEERA0081 | Select refrigerant piping, accessories and associated controls* | 40 | 60 |
UEERA0092 | Solve problems in low voltage refrigeration and air conditioning circuits* | 40 | 60 |
UEERA0094 | Verify functionality and compliance of refrigeration and air conditioning installations* | 40 | 40 |
UEERE0001 | Apply environmentally and sustainable procedures in the energy sector | 20 | 20 |
UEERL0001 | Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply* | 20 | 20 |
UEERL0002 | Attach cords, cables and plugs to electrical equipment for connection to 1000 V a.c. or 1500 V d.c.* | 20 | 20 |
UEERL0004 | Disconnect - reconnect electrical equipment connected to low voltage (LV) installation wiring* | 60 | 60 |
UEERL0005 | Locate and rectify faults in low voltage (LV) electrical equipment using set procedures* | 20 | 20 |
| Total nominal hours - core units | 1070 | 1070 |
ELECTIVE UNITS OF COMPETENCY (140 weighting points required) Competencies marked * have pre-requisite competencies. |
ELECTIVE UNITS GROUP A |
HLTAID009 | Provide cardiopulmonary resuscitation | 10 | 4 |
UETDRMP007 | Perform rescue from a live low voltage panel* | 20 | 6 |
ELECTIVE UNITS GROUP B (minimum 110 pts required) |
UEEIC0013 | Develop, enter and verify discrete control programs for programmable controllers* | 60 | 60 |
UEERA0005 | Apply safety awareness and legal requirements for ammonia refrigerant | 10 | 10 |
UEERA0006 | Apply safety awareness and legal requirements for carbon dioxide refrigerant | 10 | 10 |
UEERA0007 | Apply safety awareness and legal requirements for flammable refrigerants | 10 | 10 |
UEERA0084 | Service and repair self-contained flammable refrigerants air conditioning and refrigeration systems* | 20 | 20 |
| Total nominal hours - elective units | 140 | 120 |